| 设备所述类型 | 适用标准 |
| Radio disturbance and immunity apparatus - Measuring apparatus | SANS 216-1-1[CISPR 16-1-1 ed2.1](CISPR 16 -1 -1 ed3) |
| Radio disturbance and immunity apparatus - Conducted disturbances | SANS 216-1-2(CISPR 16-1-2 ed1.2) |
| Radio disturbance and immunity apparatus - Disturbance power | SANS 216-1-3(CISPR 16-1-3 ed2) |
| Radio disturbance and immunity apparatus - Radiated disturbance | SANS 216-1-4[CISPR 16-1-4 ed2](CISPR 16-1-4 ed3) |
| Radio disturbance and immunity apparatus - Antenna calibration test sites for 30 MHz to 1000MHz | SANS 216-1-5(CISPR 16-1-5 ed1) |
| Method of measurement of disturbances and immunity - Conducted disturbance measurements | SANS 216-2-1[CISPR 16-2-1 ed1.1](CISPR 16-2-1 ed2) |
| Method of measurement of disturbances and immunity - Measurement of disturbance power | SANS 216-2-2[CISPR 16-2-2 ed1.2](CISPR 16-2-2 ed2) |
| Method of measurement of disturbances and immunity - Radiated disturbance measurements | SANS 216-2-3[CISPR 16-2-3 ed2](CISPR 16-2-3 ed3) |
| Method of measurement of disturbances and immunity - immunity measurements | SANS 216-2-4(CISPR 16-2-4 ed1) |
| Limits for harmonic current emissions (equipment input current <= 6A per phase) | SANS 61000-3-2[IEC 61000-16-3-2 ed3](IEC 61000-3-2 ed3.2) |
| Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection | SANS 61000-3-3(IEC 61000-3-3 ed1.2)&SANS 61000-3-3(IEC 61000-3-3 Ed2) |
| Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A | SANS 61000-3-4(IEC 61000-3-4 ed1) |
| Limits Limitations and flicker in low-voltage power supply systems for equipment with rated current greater than 16A | SANS 61000-3-5[IEC 61000-3-5 ed1](IEC 61000-3-5 ed2) |
| Limits Limitation of voltage changes, voltage fluctuations and flicker in public low-voltagesupply systems - equipment with rated current <= 75A and subject to conditional connection | SANS 61000-3-11(IEC 61000-3-11 ed1) |
| Electrostatic discharge immunity test | SANS 61000-4-2[IEC 61000-4-2 ed1.2](IEC 61000-4-2 ed2) |
| Radiated, radio-frequency, electromagnetic field immunity test | SANS 61000-4-3[IEC 61000-4-3 ed3](IEC 61000-4-3 ed3. 1) |
| Electrical fast transient/burst immunity test | SANS 61000-4-4(IEC 61000-4-4 ed2) |
| Surge immunity test | SANS 61000-4-5(IEC 61000-4-5 ed2) |
| Immunity to conducted disturbances, induced by radio-frequency fields | SANS 61000-4-6[IEC 61000-4-6 ed2.2](IEC 61000-4-6 ed3) |
| General guide on harmonics and interharmonics measurements and instrumentation, forpower supply systems and equipment connected | SANS 61000-4-7[IEC 61000-4-7 ed2](IEC 61000-4-7 ed2.1) |
| Power frequency magnetic field immunity test | SANS 61000-4-8[IEC 61000-4-8 ed1.1](IEC 61000-4-8 ed2) |
| Pulse magnetic field immunity test | SANS 61000-4-9(IEC 61000-4-9 ed1 1) |
| Damped oscillatory magnetic field immunity test | SANS 61000-4-10(IEC 61000-4-10 ed1.1) |
| Voltage dips, short interruptions and voltage variations immunity tests | SANS 61000-4-11(IEC 61000-4-11 ed1) |
| Oscillatory waves immunity test | SANS 61000-4-12(IEC 61000-4-12 ed2) |
| Harmonics and interharmonics including mains signalling at a.c. power port, low frequencyimmunity tests | SANS 61000-4-13[IEC 61000-16-4-13 ed1](IEC 61000-4-13 ed1.1) |
| Voltage fluctuation immunity test | SANS 61000-4-14[IEC 61000-16-4-14 ed1.1](IEC 61000-4-14 ed1.2) |
| Test for disturbances in the frequency range 0 Hz to 150 kHz | SANS 61000-4-16(IEC 61000-4-16 ed1.1) |
| Ripple on d.c. input power port immunity test | SANS 61000-4-17[IEC 61000-4-17 ed1.1](IEC 61000-4-17 ed1.2) |
| Emission and immunity testing in transverse electromagnetic (TEM) waveguides | SANS 61000-4-20[IEC 61000-4-20 ed1.1](IEC 61000-4-20 ed2) |
| Unbalance, immunity test | SANS 61000-4-27[IEC 61000-4-17 edl](IEC 61000-4-27 ed1.1) |
| Variation of power frequency, immunity test | SANS 61000-4-28[IEC 61000-4-28 ed1.1](IEC 61000-4-28 ed1.2) |
| Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests | SANS 61000-4-29(IEC 61000-4-29 ed1) |
| Power quality measurement methods | SANS 61000-4-30[IEC 61000-4-30 ed1](IEC 61000-4-30 ed2) |
| Power supply interface at the input to telecommunication equipment Part 1: Operated byalternating (ac) derived from direct current (dc) sources | SANS 300132-1(ETS300132-1 V1) |
| Power supply interface at the input to telecommunication equipment Part 2: Operated by directcurrent (dc) | SANS 300132-2(ETS300132-2 V2.1.2) |
| Power supply interface at the input to telecommunication equipment Part 3: Operated byrectified current source, alternating current source or direct current source up to 400 V | SANS 300132-3(ETS300132-3 V1.2.1) |