可编程衰减器 MAT800

产品价格: < 面议
产品型号:MAT800
 牌:其它品牌
公司名称:深圳市汉润电子有限公司
  地:广东深圳
发布时间:2014-06-30
浏览次数:
更多
立即询价 在线咨询

产品简介

可编程衰减器

产品详细信息

 

详细介绍:

Windows98/Me/2000/XP correspondence
GP-IB, RS-232C and software for making
attenuation program are standard accessories.
Optimum for evaluation of communication quality of
such wireless communication equipments as W-CDMA,
CDMA, GSM, PDC, PHS, ETC, wireless LAN and Bluetooth.

MAT800 is a multi-functional and all-out programmable attenuator that is capable of controlling the attenuation of microwave signal at an ultra-high speed.
Features
 1.  The arbitrary attenuation programs is possible
   *128kwords built-in program memory
   *Maximum 2µs switching (readout) speed
   *Three readout modes of FREE, BURST and GATE
   *Setup of hold off period by the number of clocks or by time
2.  The software for making attenuation program is a standard accessory
3.  GP-IB and RS-232C are equipped as standard accessories
4.  Four models are prepared for every frequency band
   *model A : 1.5 to 4.5GHz
   *model B : 3.0 to 9.0GHz
   *model C : 4.5 to 13.5GHz
   *model D : 1.95 to 5.85GHz
5.  The maximum attenuation is 80dB
6.  The minimum step size of attenuation is 0.05dB 


  

 

1. Attenuation mode 2. Attenuation
Select either manual setup or programmed setup.
* Refer to "Setting of attenuation".
Set the attenuation. It is valid in the manual mode. 0 to 80 dB in 0.05 dB steps.
3. Filter 4. Readout clock
Select switching response time of attenuator.
* Refer to "About a filter".
Set readout clock of program memory. External clock and manual clock are available.
5. Program length 6. Program hold off period
Set program memory length. 8 to 131,072 words in one word step. Set hold off period of program memory, that is, the time till the next readout is started. Perform setup by number of readout clocks or by time.
* Refer to "Setting of attenuation".
7. Readout mode 8. Setup
Set readout method of program memory from Free, Burst and Gate. * Refer to "Program readout mode". Set parameters of RS-232C or GP-IB.
9. External readout clock 10. Trigger input
Connector for input of external clock for reading program memory. Connector for input of trigger signal for such read mode as Burst or Gate.
* Refer to "Program readout mode".
11. SYNC output 12. Attenuator input / output
A signal synchronized with the top address of the program memory is output.
* Refer to "Program readout mode".
SMA connector for attenuator input / output.

Setting of attenuation

Two methods are available for setup of attenuation ; manual or program. Select one by "ATTEN MODE".
●Manual mode
Set the attenuation using the rotary encoder on the front panel. Alternatively, perform setup from outside using RS-232C or GP-IB. The setup parameters in manual mode are attenuation and filter only.

  M A N U A L           2 3 . 4 5 d B  
                              3 0 µ s  

●Program mode
Read the memory storing attenuation data transferred from the computer. There are five parameters in the program mode ; readout clock, program length, hold-off period, readout mode and filter.

 

P R G M     1 0 k H z   L : 1 3 1 0 7
P : 6 . 5 5 3 5 s     F R E E   3 0 µ

 

The program readout period is the period from address 0 of the memory to address n (set by program length). The program length can be set between 8 and 131072 words in one word step. When the program is read up to address n, the attenuation data at address n is held for the hold off period (set by number of readout clocks or by time), and on termination of hold off period, the memory is read out from address 0 again.

About a filter
CR filter is inserted in the attenuation controlling line. Use when it is required to smooth the change at the moment of switching attenuation. However, it is necessary to pay attention to the relation with the readout clock. An appropriate filter value is normally 1 / 2 to 1 / 8 of the clock period.

 


The method of a program
When it is necessary to use the program mode, input the program (waveform) on a Windows computer using "Software for making attenuation program", which is provided as a standard accessory. Then transfer this attenuation data to the memory of MAT800 using RS-232C or GP-IB. Readout clock, program length, hold off period, readout mode and filter are set from the computer. Of course it is possible to set by keys on the front panel. Connect external clock and trigger signal as required.
Waveform creation
1. Standard waveforms input
The nine types of standard waveforms are prepared. They are sine wave, triangle wave, square wave, ramp wave, sinX / X, (1-ε-ax), ε-ax white noise and DC.
2. Straight line input
Two specified points are linked together by means of a straight line.
3. Arithmetic calculation input
A waveform is created by arithmetic calculation of addition, subtraction, clipping, absolute, mirror, smoothing, resize and offset.
4. One-point input
A waveform is created through input of one point at a time.

Waveform editing and file management
Waveform editing and file management may be performed using CUT, COPY, PASTE and UNDO.


 

Program readout mode

Three program readout modes are available ; Free, Burst and Gate. Readout is executed regardless of the trigger signal in the Free mode. In the Burst mode, the readout of program memory is started at the rising edge of the trigger signal, the attenuation data of the terminating address is held until the next activation. Therefore, setup of the hold off period is not permitted in the Burst mode.
In the Gate mode, one set of the readout of program memory and hold off period is repeated while the trigger signal is of a high level. The last attenuation data is held when the trigger signal goes down to a low level and then address n of program memory is read out. 

 

 

 

 

Application - wireless communication quality test by changing transmission power

With wireless communication equipments, W-CDMA, CDMA, GSM, PDC, PHS, ETC, wireless LAN and Bluetooth, the transmission power changes due to obstacles and multi-paths besides theoretical space losses, when the radio wave is transmitted through the space. This changing pattern can be simulated using MAT800 and the communication quality can be evaluated. This changing pattern can be easily created using "Software for making attenuation program". It will be very convenient if our "Shielding box ME8661A" is used for this test.

Specification

  model A model B model C model D
Frequency range   1.5 to 4.5GHz   3.0 to 9.0 GHz   4.5 to 13.5GHz   1.95 to 5.85GHz
VSWR   < 1.5 @ 2 to 4GHz
  < 2.0 @ 1.5 to 4.5GHz
  < 1.7 @ 4 to 8GHz
  < 2.2 @ 3 to 9GHz
  < 1.8 @ 6 to 12GHz
  < 2.2 @ 4.5 to 13.5GHz
  < 1.6 @ 2.6 to 5.2GHz
  < 2.1 @ 1.95 to 5.85GHz
Insertion loss
(0dB setting)
  < 2.3dB @ 2 to 4GHz
  < 2.6dB @ 1.5 to 4.5GHz
  < 3.0dB @ 4 to 8GHz
  < 3.3dB @ 3 to 9GHz
  < 3.5dB @ 6 to 12GHz
  < 3.8dB @ 4.5 to 13.5GHz
  < 2.6dB @ 2.6 to 5.2GHz
  < 2.9dB @ 1.95 to 5.85GHz

 

Attenuator
  Setting range
  Setting resolution
  Accuracy
  (at center of frequency range
    and +10dBm input)
 
 
 
  Impedance
  Filter
  Maximum input level
  Input damage level
 
  Input / output connector
Readout clock input
  Input level
  Maximum frequency
  Input impedance
  Minimum pulse width
  Input damage level
  Connector
Trigger input
  Input level
  Input impedance
  Minimum pulse width
  Input damage level
  Connector
SYNC output
  Output level
  Rise / Fall time
  Output impedance
  Connector
 
0 to 80dB
less than 0.05dB
less than ±0.5dB @ 0 to 10dB
less than ±0.8dB @ >10 to 30dB
less than ±1.0dB @ >30 to 50dB
less than ±1.5dB @ >50 to 64dB
less than ±2.0dB @ >64 to 74dB
less than ±3.0dB @ >74 to 80dB
50ohm nominal
1µs to 3ms, 1-3 step
100mW @ CW or peak power
0.8W @ average power
20W @ peak power of 1µs pulse
SMA
 
TTL level
500kHz
10kohm ±5%
more than 200ns (both of high and low)
±20V (DC + ACpeak) max
BNC
 
TTL level
10kohm ±5%
more than 1µs
±20V (DC + ACpeak) max
BNC
 
TTL level
less than 100ns
approx. 100ohm
BNC

 

 

Functions

Attenuation mode
Program mode
  Program length
  Readout clock
    Internal clock
    External clock
    Manual clock
  Hold off period
    Clock setting
 
    Time setting
  Read mode
Backup of program
Manual and Program
 
8 to 131072words, (available for setting in one word step)
 
100Hz to 500kHz, 1-2-5 step
DC to 500kHz
Due to pressing ENTER key
 
0 to 65535 clocks of readout clock
(available for each clock)
0 to 6.5535sec (by 100µs step)
Free, Burst, Gate
Program data is automatically saved when turning off.


◆Software for making attenuation program
 

Effective OS
Making waveform
  Standard waveform
    Waveform type
 
    Parameter
 
 
 
 
  Straight line
  Calculation
 
  One point input
Editing of waveform
File
 
Windows95 / 98 / Me / 2000 / XP
 
 
Sine, Triangle, Square, Ramp, sinX / X, (1-ε-ax),
ε-ax, White noise and DC
Data size, Attenuation (except DC), Offset,
Cycle (except White noise and DC), Phase (°)
(except White noise and DC), Duty ratio (%)
(only Square wave), Zero cross (only sinX / X),
Attenuation ratio ( (1-ε-ax) and ε-ax)
Link two points with line
+, -, ×, Clipping, Absolute, Mirror, Smoothing,
Resize, Offset
Input each point
Cut, Copy, Paste, Undo, Delete
New, Open, Close, Save, Save as, Data import,
Data export, Print, Printer setup, Transmit, Exit

 Others 

Display
Interface
  RS-232C
    Baud rate
  GP-IB
    Address
LCD (20characters × 2columns)
 
Standard Accessory
2,400 to 57,600
Standard Accessory
0 to 30

 ◆General

 MICRONIX Corporation receives the right to make changes in design, specification and other information without prior notice.

 

 

Operating temperature
Operating humidity
Storage temperature
Power Supply
 
Weight
Dimensions
Standard accessories
0 to 40°C (Guaranteed at 23 ±5°C)
less than 40°C / 80%RH (Guaranteed at less than 28°C / 80%RH)
-10 to +60°C / less than 80%RH
90 to 132VAC / 180 to 250VAC
  (selectable by a switch located on rear panel)
approx. 4.5kg
260 (W) × 115 (H) × 360 (D) mm (excluding projections)
Instruction manual (1pc), Power cable (1pc), Fuse (1pc),
FD for making attenuation program (1pc), RS-232C cable (1pc)

 

 

 ◆Optional

GP-IB cable
Coaxial cable
Coaxial cable
Coaxial cable
Fixed microwave attenuators
50 ohm termination
MI200
MC201
MC202
MC203
(1 to 10, 12, 13, 15, 20dB)
(SMA)

 

在线询价

您好,欢迎询价!我们将会尽快与您联系,谢谢!
  • *产品名称:
  • 采购数量:
  • 询价有效期:
  • *详细说明:
  •   100
  • *联系人:
  • *联系电话:
  • 附件: 附件支持RAR,JPG,PNG格式,大小在2M范围
验证码: 点击换一张
 
   温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。

   免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报